Fogger Installation

PROPAGATION FOR ROOTING – 3’ TO 4’ BENCHES

The height of the fogger assembly should be 18” to 30” above the propagation material. The distance between the fogger assemblies should be 3 feet. (Place the lateral above the center of a 3’ to 4’ bench)

Graphic Info

PROPAGATION FOR ROOTING – WIDE BENCHES

For wide benches, up to 8’, use two lines of foggers equally distanced from the center of the bench. For large areas, use one row of foggers for every 4’ width of area to be fogged. 4-Way Fogger units should be placed at 45° angles to one another.

Graphic InfoGraphic Info

HUMIDIFICATION AND COOLING

  • In order to maximize the cooling effect, exhaust fans are recommended to exchange the air about 20 times per hour.
  • Cooling considerations include placing foggers as high as possible, avoid spraying against the roof or structure and prevent precipitation by adjusting the cycle time.
  • These recommendations are general and should be applied in accordance with local conditions and limitations.
  • Duration of pulse and interval is to be fine-tuned according to local conditions; the timing provided is just a starting point.
  • For crops that are not sensitive to wetting, the pulse can be prolonged, and/or the interval shortened.
  • The spacing in the General Spacing and Operation chart give some reference points between spacing and operation intervals and other spacing can certainly be used with foggers.

Graphic Info

Graphic Info