2" Compact LP Disc-Kleen Technical

Specifications

  • Inlet: 2” male pipe threaded
  • Outlet: 2” female pipe threaded
  • Flush port: 2” female pipe threaded
  • Maximum operating pressure: 
    • Standard and Low Flow Models: 90 psi
    • High Pressure Model: 140 psi
  • Minimum pressure for backflush: 30 psi
  • Minimum flow for backflush:
    • - Standard - 35 GPM
    • - Low Flow - 20 GPM
  • Minimum allowable pH: 5
  • Weight: 32 lbs.

Materials

  • Flush valves: Plastic
  • Seals: Nitrilo rubber, EPDM
  • Filter and spine: Polypropylene
  • Discs: Polypropylene
  • Clamp and screws: Stainless steel

Illustration of 2 inch Compact filtration process

Disc Filter Technology

Grooves in the disc rings criss-cross to form a network that traps debris between and on the outside of the discs.

How It Works

As dirty water is pumped into the filter, and pressure increases, the water compresses the disc rings together tightly. The water is then forced to flow through the grooves of the disc rings, where debris is trapped, releasing only clean water to the irrigation system.

Automatic Backflush Technology

The discs separate and nozzles spray the discs with clean water - inside and out, removing debris.

2” Compact Filter Flow Rate vs. Pressure Loss Graph

2in Compact Flow Rate vs. Pressure Loss Chart

2” Compact Maximum Flow Rate for Standard and Low Flow Models

Water Quality

  • Good Water Quality: Municipal water supply or well water from a clean aquifer with no sand, iron or manganese.
  • Average Water Quality: Wells with small amounts of sand (< 2 ppm) or clear surface water which includes lakes, ponds, reservoirs and canals.
  • Poor Water Quality: Well water with sand up to 10 ppm of sand or surface water in hot climates with increased biological growth and no chemical treatment which includes lakes, ponds, reservoirs and canals.
  • Very Poor Water Quality: Well water with greater than 10 ppm of sand including rivers, muddy canals, lakes and ponds with severe run off deposits and raw municipal wastewater.
  • Greater than 3ppm Sand or Silt: May require a pre-filter such as a Hydrocyclone.