SPECIFICATIONS
- Inlet and Outlet Connections:
- 2" LP Disc-Kleen - 4" Grooved
- 3" LP Disc-Kleen - 6" Grooved
- Backflush Valve Flush Port: 2" Male Pipe Thread
- Maximum Operating Water Pressure: 90 psi
- Minimum Pressure for Backflush: 30 psi
- Minimum Backflush Flow Per Spine: 35 GPM
- Minimum Allowable pH: 5
- Drain Manifold: 2" Grooved Outlet Connection
WATER QUALITY GUIDELINES
GOOD WATER QUALITY: Municipal water supply or well water from a clean aquifer with no sand, iron or manganese.
AVERAGE WATER QUALITY: Wells with small amounts of sand (<2 ppm) or clean surface water which includes lakes, ponds, reservoirs and canals.
POOR WATER QUALITY: Well water with sand up to 10 ppm or surface water in hot climates with increased biological growth and no chemical treatment which includes lakes, ponds, reservoirs and canals.
VERY POOR WATER QUALITY: Well water with greater than 10 ppm of sand including rivers, muddy canals, lakes and ponds with severe run off deposits and raw municipal wastewater.
GREATER THAN 3 PPM SAND OR SILT: May require a pre-filter such as a hydrocyclone.