Description of System Operation

FILTRATION MODE
Unfiltered water enters via the inlet manifold. During filtration the inlet ports are open and water flows from the top to the bottom across the sand layer. The filtered water exits the system through the outlet manifold.

BACKFLUSH MODE
During backflush the inlet port closes and the backflush port opens which reverses the flow of water in the filter. Clean water from the other filters flows into the filter from the bottom lifting the sand media and freeing the accumulated debris. Debris flushes out the top of the filter through the backflush manifold.
SPECIFICATIONS
Maximum Flow Rates:
Good Quality Water - 25 GPM/sq. ft.
Dirty Water - 20 GPM/sq. ft.
Minimum Filtration Pressure: 15 psi
Minimum Backflush Pressure: 30 psi
Maximum Operating Pressure: 85 psi
Sand Requirement: 1,300 lbs. per 48” Tank
Manifolds: Polypropylene
Leg Height: Adjustable
Backflush Valve: 4” Plastic Grooved Valve