NETAFIM USA Landscape & Turf Product Catalog | 1 ABOUT NETAFIM TABLE OF CONTENTS FROM PIONEERING DRIP IRRIGATION FOR AGRICULTURE, TO INNOVATIVE WATER CONSERVING SOLUTIONS IN LANDSCAPE IRRIGATION First founded by farmers and agronomists in 1965, who recognized drip irrigation as a solution to one of the world’s most urgent problems - lack of quality water for food production - Netafim has grown today to become the recognized global leader in the development of low-volume, drip irrigation solutions for a diverse range of applications. As a pioneer in developing water-conserving irrigation technologies for the world’s agriculture community, Netafim continues to leverage its five decades of innovation to provide today’s landscape professionals with comprehensive solutions for efficient and effective irrigation even in the most challenging residential and commercial landscapes. A complete line of technologically advanced, environmentally sound, drip irrigation and water conservation products deliver water savings, low maintenance and worry-free operation. Recognizing the evolving needs of a diverse and dynamic landscape industry, Netafim addresses the challenges of modern landscapes through innovative products, education, training and research. Together, we can create sustainable landscapes and grow more with less. DRIPLINES Typical Design Layouts.........................................................2 Sizing of Headers...................................................................6 Soil Types and Slopes...........................................................7 General Guidelines.................................................................8 Techline® Copper. ..................................................................9 Techline® HCVXR-RW and RWP....................................... 11 Techline® CV XR.................................................................. 13 Techline® CV. ....................................................................... 15 Techline® DL......................................................................... 17 Techline® RW and RWP. .................................................... 19 Techline® EZ......................................................................... 21 12mm & 17mm Fittings.................................................... 23 TechLock Fittings................................................................ 24 Installation Tools................................................................. 24 Air/Vacuum Relief Air Vents. ............................................ 25 Combination Air Vents....................................................... 25 Automatic Flush Valves..................................................... 26 In-Line Check Valve............................................................. 26 Operation/Pressure Indicator Stakes.............................. 27 CONTROL ZONE KITS Low Volume Control Zone Kits......................................... 28 1” Control Zone.................................................................... 30 REGULATING Pressure Regulators........................................................... 31 VALVES Series 80 Nylon Valves....................................................... 33 Iron, Nylon and PVC Valves............................................... 35 FILTERS Manual Disc Filters............................................................. 37 Manual Screen Filters. ....................................................... 39 2” Compact LP Disc-Kleen Filter...................................... 40 2” and 3” LP Disc-Kleen Filter........................................... 42 Apollo Disc-Kleen Filter...................................................... 44 WATER METERS Hydrometers........................................................................ 46 Octave Ultrasonic Water Meters...................................... 48 Water Meters. ...................................................................... 50 POINT SOURCE COMPONENTS Point Source Design........................................................... 54 Self-Piercing Emitters......................................................... 55 Techflow Emitters.............................................................. 56 BD and WP Emitters........................................................... 57 NetBow. ................................................................................ 58 Dr. Zip. ................................................................................... 59 Polyethylene Tubing. .......................................................... 60 Micro-Tubing........................................................................ 61 Micro-Tube Fittings............................................................. 62 DESIGN INFORMATION Dripline Calculations........................................................... 63 Application Rates................................................................ 64 Friction Loss. ....................................................................... 66 Web Resources. .................................................................. 69 Warranty Information......................................................... 70

2 | Landscape & Turf Product Catalog NETAFIM USA TYPICAL LAYOUTS ON-SURFACE DESIGN For Use with Techline® Dripline On-Surface Designs (On Top of Soil, Covered with Mulch). Use one manual flush valve for every 15 GPM of zone flow. • Position as near as possible to the halfway point of the loop. • Install in an area where flushing about one gallon of water will not cause flooding. For Techline Copper, CV XR and CV, use a manual flush valve. For Techline DL, EZ and RW, use an automatic flush valve and an air/vacuum relief air vent. • Start rows of Techline 2” from hardscapes and 4” from softscapes. • Flow per zone not to exceed 5 GPM. For easy installation, use Netafim’s Low Volume Control Zone Kits which include a pre-assembled valve, filter and pressure regulator. MANUAL FLUSH VALVE Use one staple for: • Every 3’ of Techline in sand, every 4’ in loam and every 5’ in clay. • Use two staples over each tee, elbow or cross. • Recommend use of a U-shaped staple that is less likely to pinch the dripline. STAPLES TECHLINE OPTIONAL COMPONENTS LOW VOLUME CONTROL ZONE KIT Place before water meter. Automatic continuous acting mini air vent models available in ½” and ¾” sizes, up to 150 psi. CONTINUOUS ACTING AIR VENT MASTER VALVE Water Meter used to measure water usage for irrigation system. Plastic version available in ¾” and 1” sizes. Metal version available in ¾” to 6” sizes. WATER METER Water Flow Flag raises to indicate system is operating. • Flag position down: closed • Flag position halfway: 7 psi • Flag position upright: 10 psi or higher • Use Mister Indicator with Techline CV and HCVXR applications OPERATION FLAG

NETAFIM USA Landscape & Turf Product Catalog | 3 TYPICAL LAYOUTS SUBSURFACE DESIGN For Use with Techline® Dripline Designs. Bury Driplines Evenly Throughout the Zone from 4” to 6” Deep or on-surface under Mulch. Use one staple for: • Every 3’ of Techline in sand, every 4’ in loam and every 5’ in clay. • Use two staples over each tee, elbow or cross. • Recommend use of a U-shaped staple that is less likely to pinch the dripline. STAPLES Start rows of Techline 2” from hardscapes and 4” from softscapes. TECHLINE PVC is most often used for Techline manifolds in subsurface systems. Use Techline blank tubing as supply and exhaust headers on zones under 5 GPM. OPTIONAL COMPONENTS LOW VOLUME CONTROL ZONE KIT For easy installation, use Netafim’s Low Volume Control Zone Kits which include a pre-assembled valve, filter and pressure regulator. SUPPLY AND EXHAUST HEADERS • Normally placed along exhaust header or at the point farthest away from the source. • Install in a valve box with gravel sump. MANUAL FLUSH VALVE Water Meter used to measure water usage for irrigation system. Plastic version available in ¾” and 1” sizes. Metal version available in ¾” to 6” sizes. WATER METER MASTER VALVE NOTES: • Add an automatic flush valve when using Techline DL, EZ or RW. • Add an air relief valve at the highest point in the system when using Techline DL, EZ or RW. Place before water meter. Automatic continuous acting mini air vent models available in ½” and ¾” sizes, up to 150 psi. CONTINUOUS ACTING AIR VENT

4 | Landscape & Turf Product Catalog NETAFIM USA TYPICAL LAYOUTS SUBSURFACE DESIGN For Use with Techline® Dripline Designs. Bury Driplines Evenly Throughout the Zone from 4” to 6” Deep. Netafim offers comprehensive design details, installation information and a dripline calculator on our website, www.netafimusa.com Most often used in subsurface systems. Use Techline blank tubing as supply and exhaust headers on zones under 5 GPM. SUPPLY AND EXHAUST HEADERS Use one staple for: • Every 3’ of Techline in sand, every 4’ in loam and every 5’ in clay. • Use two staples over each tee, elbow or cross. • Recommend use of a U-shaped staple that is less likely to pinch the dripline. STAPLES Start rows of Techline 2” from hardscapes and 4” from softscapes. TECHLINE LOW VOLUME CONTROL ZONE KIT For easy installation, use Netafim’s Low Volume Control Zone Kits which include a pre-assembled valve, filter and pressure regulator. • Normally placed along exhaust header or at the point farthest away from the source. • Install in a valve box with gravel sump. MANUAL FLUSH VALVE NOTES: • Add an automatic flush valve when using Techline DL, EZ or RW. • Add an air relief valve at the highest point in the system when using Techline DL, EZ or RW.

NETAFIM USA Landscape & Turf Product Catalog | 5 TYPICAL LAYOUTS SUBSURFACE/ON-SURFACE DESIGN CONTOURS Driplines provide a flexible solution for irrigating around contoured areas and around confined planters or shrubs. LATERAL PLACEMENT Place laterals 6” from any hardscape or from the outside of uncontained landscapes. Place laterals perpendicular to (across) slopes, if any. END FEED For Techline Copper, CV XR, or CV layouts. End feed configurations are generally used for short or medium length installations. CENTER FEED For Techline DL, EZ, or RW system applications in medians or island use center feed configuration for long narrow areas. Use Techline blank tubing for supply and exhaust headers on zones less than 5 GPM. Fitting for PVC greater than 1½” TLAVR TLFV-1 LVCZ KIT LVCZ KIT TLSOV TLFV-1 CLOSED LOOP SYSTEMS:

6 | Landscape & Turf Product Catalog NETAFIM USA LVCZ KIT TLS6 TLTEE TLCROS TLSOV TYPICAL LAYOUTS TREE RING LAYOUT For Techline® Techline Copper, CV XR, and CV SIZING OF HEADERS SUPPLY AND EXHAUST HEADERS TOTAL ZONE FLOW PIPE SIZE PROPER SIZING OF SUPPLY AND EXHAUST HEADERS (17mm Techline Dripline) UP TO 5 GPM 17mm TECHLINE TUBING OR ½” SCH 40 PVC OR ½” POLY TUBING 5.1 TO 8 GPM ¾” SCH 40 PVC OR ¾” POLY TUBING 8.1 TO 13 GPM 1” SCH 40 PVC OR 1” POLY TUBING 13.1 TO 22 GPM 1 ¼” SCH 40 PVC OR 1 ¼” POLY TUBING 22.1 TO 31 GPM 1 ½” SCH 40 PVC OR 1 ½” POLY TUBING TOTAL ZONE FLOW PIPE SIZE UP TO 6 GPM ½” CLASS 315 PVC 6.1 TO 10 GPM ¾” CLASS 200 PVC 10.1 TO 17 GPM 1” CLASS 200 PVC 17.1 TO 27 GPM 1 ¼” CLASS 200 PVC 27.1 TO 35 GPM 1 ½” CLASS 200 PVC 5 feet per second velocity NOTE: A 45 psi pressure regulator is recommended to obtain maximum run lengths and maximum zone size when installing 17mm Techline driplines.

NETAFIM USA Landscape & Turf Product Catalog | 7 SOIL TYPES AND SLOPES Determining the Proper Emitter to Use is Based Primarily on the Soil Type and Slope. The Maximum Precipitation Rates Chart from the U.S. Department of Agriculture shows the ability of various soils to absorb water. This information is important because it is the best way to show how different soils manage water. In the case of Coarse Sandy Soil on a 0 to 5% Slope, it can absorb 2.00” of water if covered with vegetation. Conversely, a heavy clay/clay loam soil can only accept about 0.20”. This means that sandy soil does not hold water as well as tighter soils. It also means that sandy soil will not radiate the water as far laterally and upward as a tighter soil. As such, care needs to be taken when deciding what emitter flow rate to use and how far apart the emitters can be from each other. And as the slope increases, this takes on even greater importance. SLOPES AND BERMS Techline Copper, CV XR, and CV emitters have a built-in check valve. This allows Techline Copper to hold back up to a 8.3’, Techline CV and CV XR up to 4.6‘ column of water. As such, designing Techline Copper, CV XR, and CV on slopes and berms is very easy. • Techline Copper, CV XR, and CV should be installed perpendicular to (across) slopes. • In the upper 2/3 of the slope, space Techline Copper, CV XR, and CV per General Guidelines tables. • In the lower 1/3 of the slope, increase the distance between rows by 25%. • For every 4.6’ elevation change, when using Techline CV or CV XR: - Split the slope into separate zones, or - Install a Netafim in-line check valve (TLCV050M1). • For every 8.3’ elevation change, when using Techline Copper: - Split the slope into separate zones, or - Install a Netafim in-line check valve (TLCV050M1). 18" at Top Up To +25% 22 1/2" at Bottom 2/3 1/3 MAXIMUM PRECIPITATION RATES (Inches per Hour) SOIL TEXTURE COARSE SANDY SOIL COARSE SANDY SOIL OVER COMPACT SUBSOIL LIGHT SANDY SOIL LIGHT SANDY SOIL OVER COMPACT SUBSOIL UNIFORM SILT LOAM SILT LOAM OVER COMPACT SUBSOIL HEAVY CLAY / CLAY LOAM 0% TO 5% SLOPE 2.00 2.00 2.00 1.50 1.50 1.00 1.00 1.00 1.75 1.50 1.25 1.00 1.00 0.75 0.75 0.40 1.75 1.00 1.25 0.80 1.00 0.60 0.75 0.40 1.25 0.75 1.00 0.50 0.75 0.40 0.50 0.30 1.00 0.50 0.80 0.40 0.60 0.30 0.40 0.20 0.60 0.30 0.50 0.25 0.40 0.15 0.30 0.10 0.20 0.15 0.15 0.10 0.12 0.08 0.10 0.06 COVERED BARE 5% TO 8% SLOPE COVERED BARE 8% TO 12% SLOPE COVERED BARE COVERED BARE 12% TO 20% SLOPE Note: The above average values are for reference purposes. Data may vary with respect to actual soil and site conditions. Data from USDA.

8 | Landscape & Turf Product Catalog NETAFIM USA GENERAL GUIDELINES EMITTER FLOW 0.33 GPH 0.53 GPH 0.77 GPH 0.33 GPH 0.53 GPH 0.77 GPH EMITTER SPACING 18” 12“ 12“ 18” 18” 12“ LATERAL (ROW) SPACING APPLICATION RATE (INCHES/HOUR) TIME TO APPLY ¼” OF WATER (MINUTES) SHRUB & GROUNDCOVER TURF SANDY / COARSE Following these maximum spacing guidelines, emitter flow selection can be increased if desired by the designer. On-surface or bury evenly throughout the zone to a maximum of 6” Bury evenly throughout the zone from 4”to 6” BURIAL DEPTH 18” 20” 22” 12” 18” 20” 12” 14” 16” 18” 21” 24” 18” 21” 24” 16” 18” 20” 0.24 0.21 0.19 0.85 0.56 0.51 1.23 1.05 0.92 0.24 0.20 0.18 0.38 0.32 0.28 0.92 0.82 0.74 64 71 78 18 27 30 12 14 16 64 74 85 40 46 53 16 18 20 SOIL TECHLINE® COPPER HCVXR - RW/RWP GENERAL GUIDELINES CLAY LOAM SANDY / COARSE CLAY LOAM EMITTER FLOW 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH EMITTER SPACING 18” 12“ 12” 12“ 18” 18” 12“ 12“ LATERAL (ROW) SPACING APPLICATION RATE (INCHES/HOUR) TIME TO APPLY ¼” OF WATER (MINUTES) SHRUB & GROUNDCOVER TURF CLAY LOAM SANDY COARSE CLAY LOAM SANDY COARSE Following these maximum spacing guidelines, emitter flow selection can be increased if desired by the designer. On-surface or bury evenly throughout the zone to a maximum of 6” Bury evenly throughout the zone from 4”to 6” BURIAL DEPTH 18” 20” 22” 12” 18” 20” 12” 14” 16” 12” 14” 16” 18” 21” 24” 18” 21” 24” 16” 18” 20” 16” 18” 20” 0.19 0.17 0.15 0.64 0.55 0.43 0.98 0.84 0.65 1.48 1.27 1.11 0.19 0.16 0.14 0.30 0.26 0.23 0.73 0.65 0.59 1.11 0.99 0.89 SOIL TECHLINE® CV, CV XR, DL & EZ GENERAL GUIDELINES 80 89 97 23 27 35 15 18 23 10 12 13 80 93 106 50 58 66 20 23 26 13 15 17

NETAFIM USA Landscape & Turf Product Catalog | 9 TECHLINE® COPPER 17mm DRIPLINE The Highest Performing Dripline in the Industry. FEATURES & BENEFITS CHECK VALVE High check valve holds back 8.3’ of water for distribution uniformity. ANTI-SIPHON Prevents debris from entering the emitter outlet at system shut-down. PRESSURE COMPENSATING Delivers precise, equal amounts of water over a broad pressure range. LARGE AND EFFECTIVE FILTER AREA Prevents penetration of coarse particles inside flow path. Superb clog reistance for effecient irrigation. CONTINUOUS SELF FLUSHING EMITTER Flushes debris as it’s detected. ONE PIECE DRIPLINE CONSTRUCTION Reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Bending radius of 7” adapts to any planting area shape. WIDE COPPER STRIPE SHIELDS AGAINST ROOT INTRUSION • Wide stripe design makes it easy to identify the dripline as Techline Copper • Embedded Cupron® provides a layer of defense against root intrusion • Cupron® copper oxide (Cu20) technology will not wash out, wear off or leach out. Remaining effective throughout the life of the product • Cupron® copper oxide is approved for use by the EPA ensuring peace of mind POWER OF CUPRON® COPPER OXIDE ANTIMICROBIAL TECHNOLOGY Copper is used in many industries for its antimicrobial properties and is recognized by the United States Environmental Protection Agency (US EPA) as the first anitmicrobial metal. It is an essential nutrient for humans and bacteria, but in specific concentrations, it can serve as an antimicrobial agent. Cupron’s® proprietary technology is impregnated at specific concentrations to our patent-pending process ensuring it remains effective throughout the life of the product. SPECIFICATIONS • Emitter flows: 0.33, 0.53, 0.77 • Emitter spacings: 12”, 18”, 24” (24” spacing available on 1,000 coils only) • Maximum system pressure: 58 psi • Minimum pressure: 21.8 psi • Tubing diameter: 0.66” OD; 0.56” ID, 0.05” wall • Coil lengths: 100’, 250’, 500’, 1,000’ • Recommended filtration: 120 mesh • Diaphragm: molded silicon APPLICATIONS • Subsurface or on-surface Turf, shrubs, trees and flowers • Sports turf, tennis courts, golf courses • Slopes • Curved, angular or narrow planting areas • High traffic/high liability areas • Areas subject to vandalism • At-grade windows • Green walls, green roofs • Raised planters RECYCLED CONTENT Techline Copper qualifies for LEED credit 4.2 as it contains a minimum of 20% polyethylene post-consumer recycled material. LASER ETCHING Model number laser etched on dripline. MORE PROTECTION AGAINST CLOGGING The large surface area of the filter increases longevity and prevents dirt particles from settling in the dripper. 17 YEAR WARRANTY * Free of emitter plugging due to root intrusion from the date of original delivery. *See Warranty Information on page 70. COPPER

10 | Landscape & Turf Product Catalog NETAFIM USA FLOW CODE EMITTER SPACING COIL LENGTH *MODEL NUMBER TLHCVXRX-1201 TLHCVXRX-12025 TLHCVXRX-1205 TLHCVXRX-1210 TLHCVXRX-1801 TLHCVXRX-18025 TLHCVXRX-1805 TLHCVXRX-1810 TLHCVXRX-2410 12” 18” 24“ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 1,000‘ 3 5 7 FLOW RATE 0.33 0.53 0.77 BLANK TUBING 100’ 250’ 500‘ 1,000’ TLHCVXR-001 TLHCVXR-0025 TLHCVXR-005 TLHCVXR-010 COIL LENGTH MODEL NUMBER ORDERING INFORMATION TECHLINE® COPPER TLHCVXR3-1210 3 1 2 A SAMPLE MODEL NUMBER Techline HCVXR Dripline = TLHCVXR A EMITTER SPACING 3 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 4 100’ 250’ 500‘ 1,000’ = 01 = 025 = 05 = 10 EMITTER FLOW RATE 0.33 GPH 0.53 GPH 0.77 GPH = 3 = 5 = 7 1 2 SPECIFYING & ORDERING INFORMATION * Substitute X in the Model Number with Flow Code FLOW RATE VS. PRESSURE 1.25 1.0 0.77 0.53 0.33 0 10 20 30 40 50 58 PRESSURE (psi) FLOW RATE (GPH) 0.53 GPH 0.33 GPH Techline Copper emitters open at 21.8 psi and close at 3.6 psi. 0.77 GPH FLOW PER 100 FEET 12” 18” 24” 0.33 EMITTER 0.53 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM 33.0 0.55 53.0 0.88 77.0 1.28 22.0 0.37 35.3 0.59 51.3 0.86 16.5 0.28 26.5 0.44 38.5 0.64 0.77 EMITTER INLET PRESSURE MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) 25 psi 30 psi 35 psi 40 psi 45 psi 50 psi 55 psi 60 psi EMITTER SPACING 12” 18“ 24” EMITTER FLOW (GPH) 0.33 0.53 0.77 0.33 0.53 0.77 0.77 237 173 136 335 246 192 244 327 240 187 464 341 266 338 385 282 221 546 401 314 400 429 315 247 611 449 351 446 467 342 268 663 488 381 486 499 366 287 710 521 408 520 528 387 303 752 552 432 550 554 406 318 788 579 453 578 * See General Guideline on Page 7. Exterior Features Inhibiting Root Growth Interior Mechanisms Preventing System Clogging Emitter Design with Physical Root Barrier and Large Filtration Bath Area New External Copper Stripe Copper Emitter Anti-Siphon Mechanism Pressure Compensation Chamber Continuous Self Flushing Mechanism

NETAFIM USA Landscape & Turf Product Catalog | 11 TECHLINE® HCVXR-RW & RWP 17mm DRIPLINE For Reclaimed Water Use. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Reclaimed (recycled) water use • For irrigation with non-potable/reclaimed water and soil loading SPECIFICATIONS • Emitter flows: 0.33, 0.53, 0.77 • Emitter spacings: 12” and 18” • Pressure compensation range: 21.8 to 58 psi • High check valve: holds back 8.3’ of water • Bending radius: 7” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 21.8 psi • Tubing diameter: 0.66” OD; 0.56” ID, 0.050” wall • HCVXR-RW coil lengths: 500’ and 1,000’ • HCVXR-RWP coil length: 500’ • Recommended minimum filtration: 120 mesh • Diaphragm: molded silicon • ISO 9261 Standard Compliance FEATURES & BENEFITS LONG LASTING PROTECTION THROUGHOUT THE LIFE OF THE DRIPLINE Cupron® copper oxide will not wash off, wear off and does not leach out of the emitter providing superior root intrusion resistance. PATENTED EMITTER DESIGN WITH PHYSICAL ROOT BARRIER Offset flow path, extra large bath area and raised outlet prevent root intrusion. HIGH CHECK VALVE IN EACH EMITTER The high check valve is great on slopes because it holds back 8.3’ of water (elevation change) keeping the dripline charged for even distribution of water with no emitter drainage in low spots. EMITTER WITH ANTI-SIPHON FEATURE Emitter outlet is sealed at system shutdown blocking debris from entering the dripline after irrigation. PRESSURE COMPENSATING WITH CONTINUOUS SELF-FLUSHING Delivers precise, equal amounts of water over wide pressure range while continuously flushing debris throughout operation. THREE EMITTER FLOW RATES Achieve maximum design flexibility with three emitter flow rates - the most options offered in the industry. 17 YEAR WARRANTY Netafim stands behind Techline HCVXR-RW/RWP with an unprecedented limited warranty for root intrusion. We warrant Techline HCVXR-RW/RWP to be free of emitter plugging due to root intrusion for a period of 17 years* from the date of original delivery. * Refer to the Warranty Page for more details. TECHLINE HCVXR-RW AND RWP ARE DESIGNED FOR RECLAIMED WATER USE ONLY Reclaimed, reuse or recycled water is municipally-treated, non-potable water deemed appropriate for use in irrigation systems and not wastewater being dispersed into the soil for additional treatment. Please consult your local Water Management District for regulations regarding the type of water being used, and its proper system design. Netafim USA can provide assistance on drip dispersal that uses primary or secondary and tertiary wastewater. Please contact Netafim USA Customer Service for more information. Solid purple dripline TECHLINE HCVXR-RWP Purple striped dripline TECHLINE HCVXR-RW TECHLINE RW& RWP QUALIFIES FOR USE ON LEED PROJECTS

12 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® HCVXR-RW & RWP 1.25 1.0 0.77 0.53 0.33 0 10 20 30 40 50 58 PRESSURE (psi) FLOW RATE (GPH) 0.53 GPH 0.33 GPH Techline HCVXR-RW and RWP emitters open at 21.8 psi and close at 3.6 psi. FLOW RATE VS. PRESSURE 0.77 GPH SPECIFYING MODEL NUMBER TLHCVXR-RW3-1210 3 1 A SAMPLE MODEL NUMBER Techline HCVXR-RW Dripline = TLHCVXR-RW A Techline HCVXR-RWP Dripline = TLHCVXR-RWP EMITTER SPACING 2 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 3 100’ 250’ 500‘ 1,000’ = 01 = 025 = 05 = 10 EMITTER FLOW RATE 0.33 GPH 0.53 GPH 0.77 GPH = 3 = 5 = 7 1 2 FLOW CODE EMITTER SPACING COIL LENGTH *MODEL NUMBER TLHCVXRX-1201 TLHCVXRX-12025 TLHCVXRX-1205 TLHCVXRX-1210 TLHCVXRX-1801 TLHCVXRX-18025 TLHCVXRX-1805 TLHCVXRX-1810 TLHCVXRX-2410 12” 18” 24“ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 1,000‘ 3 5 7 11 FLOW RATE 0.33 0.53 0.77 ORDERING INFORMATION BLANK TUBING 500’ 500‘ 1,000’ TLHCVXR-RW005 TLHCVXR-RWP005 TLHCVXR-RW010 COIL LENGTH MODEL NUMBER FLOW PER 100 FEET 12” 18” 0.33 EMITTER 0.53 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM 33.0 0.55 53.0 0.88 77.0 1.28 22.0 0.37 35.3 0.59 51.3 0.86 0.77 EMITTER INLET PRESSURE MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) 25 psi 30 psi 35 psi 40 psi 45 psi 50 psi 55 psi 60 psi 237 173 136 335 246 192 327 240 187 464 341 266 385 282 221 546 401 314 429 315 247 611 449 351 467 342 268 663 488 381 499 366 287 710 521 408 528 387 303 752 552 432 554 406 318 788 579 453 EMITTER SPACING 12” 18“ EMITTER FLOW (GPH) 0.33 0.53 0.77 0.33 0.53 0.77 * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.

NETAFIM USA Landscape & Turf Product Catalog | 13 TECHLINE® CV XR 17mm DRIPLINE Enhanced with Copper for Long Lasting Protection. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Sports turf, tennis courts, golf courses • Slopes • Longer lateral runs • Curved, angular or narrow planting areas • High traffic/high liability areas • Areas subject to vandalism • High wind areas • At-grade windows • Green walls, green roofs • Raised planters SPECIFICATIONS • Broad choice of emitter flow rates: 0.42, 0.61, 0.92 GPH. • Emitter spacings: 12” and 18”. • Pressure compensated range: 14.5 - 58 psi. • Check Valve (CNL): Emitters open at 14.5 psi and shut off at 2 psi to hold back 4.6’ of water. • Recommended filtration: -120 mesh. • Coil length: 250’ & 1000’. FEATURES & BENEFITS CUPRON ENHANCED DRIPPER Copper Oxide is embedded into the emitter labyrinth and is an effective deterrent against root intrusion without any reliance on chemicals. Cupron Copper oxide provides long lasting protection due to non migrating active ingredients, lasting the life of the Techline. CHECK VALVE (CNL) All emitters turn on and off at the same time, maximizing balance of application. Holds back up to 4.6’ of water. No low emitter drainage, great on slopes, and delivers more precise watering. ANTI-SIPHON MECHANISM Prevents contaminants from being drawn into the dripper, making it ideal for sub surface applications. PRESSURE COMPENSATED Precise and equal amounts of water delivered over a broad pressure range ensuring 100% uniformity of water and nutrient distribution along the laterals. PHYSICAL ROOT BARRIER Offset flow path, extra large bath area, and raised outlets provide another level of protection by physically blocking roots from the labyrinth. CONTINUOUS SELF-FLUSHING MECHANISM Flushes debris throughout operation, while ensuring constant dripper operation. LARGE FILTRATION AREA The Techline™ CV XR Dripper is highly resistant to clogging from poor quality water, thus increasing filtration efficiency. TURBONET™ TurboNet technology improves dripper performances by widening the tooth pattern, maximizing flow path velocity, allowing contaminants to pass easily through the dripper, virtually eliminating plugging. 17 YEAR WARRANTY * Free of emitter plugging due to root intrusion from the date of original delivery. *See Warranty Information on page 70.

14 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® CV XR 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 58 PRESSURE (psi) FLOW RATE (GPH) FLOW RATE VS. PRESSURE Techline CV XR emitters open at 14.5 psi and close at 2 psi. 0.61 GPH 0.42 GPH 0.92 GPH FLOW PER 100 FEET 12” 18” 0.42 EMITTER 0.61 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM 42.3 0.71 60.8 1.01 92.5 1.54 28.2 0.47 40.5 0.68 61.6 1.03 0.92 EMITTER INLET PRESSURE MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi 242 190 144 344 270 204 302 238 180 429 338 257 380 299 227 540 426 323 436 343 260 620 489 371 480 378 287 684 539 410 500 393 298 713 561 426 EMITTER SPACING 12” 18“ EMITTER FLOW (GPH) 0.42 0.61 0.92 0.42 0.61 0.92 SPECIFYING MODEL NUMBER TLCVXR-4-1210 3 1 A SAMPLE MODEL NUMBER Techline HC XR Dripline = TLCVXR A EMITTER SPACING 2 12” 18” = 12 = 18 COIL LENGTH 3 250’ 1,000’ = 025 = 10 EMITTER FLOW RATE 0.42 GPH 0.61 GPH 0.92 GPH = 4 = 6 = 9 1 2 BLANK TUBING 250‘ 1,000’ TLCVXR0025 TLCVXR010 COIL LENGTH MODEL NUMBER * See General Guideline on Page 7. EMITTER SPACING COIL LENGTH MODEL NUMBER TLCVXR4-12025 TLCVXR4-1210 TLCVXR4-18025 TLCVXR4-1810 12” 18” 250’ 1,000’ 250’ 1,000’ FLOW RATE ORDERING INFORMATION 0.42 GPH TLCVXR6-12025 TLCVXR6-1210 TLCVXR6-18025 TLCVXR6-1810 12” 18” 250’ 1,000’ 250’ 1,000’ 0.61 GPH TLCVXR9-12025 TLCVXR9-1210 TLCVXR9-18025 TLCVXR9-1810 12” 18” 250’ 1,000’ 250’ 1,000’ 0.92 GPH

NETAFIM USA Landscape & Turf Product Catalog | 15 Large inlet filtration area (entire base of emitter) Diaphragm Emitter outlet (top of emitter) Physical root barrier prevents roots from penetrating the emitter Unique patented TurboNet technology wide flow path allows more control of water flow and less chance for clogging Check valve (CV) mechanism Anti-vacuum (AS) mechanism prevents suction of dirt into the dripline TECHLINE® CV 17mm DRIPLINE Maximum Uniformity in Subsurface and On-surface Including Slopes. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Sports turf, tennis courts, golf courses • Slopes • Longer lateral runs • Curved, angular or narrow planting areas • High traffic/high liability areas • Areas subject to vandalism • High wind areas • At-grade windows • Green walls, green roofs • Raised planters SPECIFICATIONS • Broadest choice of emitter flow rates: 0.26, 0.42, 0.61 and 0.92 GPH • Emitter spacings: 12”, 18“ and 24” (24” spacing available for 0.61 and 0.92 GPH only) • Pressure compensation range:1 4.5 to 58 psi • Bending radius: 7” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 14.5 psi • Tubing diameter: 0.66“ OD; 0.56” ID; 0.050” wall • Coil lengths: 100’, 250’, 500‘, 1,000’ • Recommended minimum filtration: 120 mesh • Diaphragm made of silicon • ISO 9261 Standard Compliance FEATURES & BENEFITS 2 psi CHECK VALVE IN EACH EMITTER All emitters turn on and off at the same time, maximizing balance of application. Holds back up to 4.6’ of water (elevation change). No low emitter drainage, great on slopes. Delivers more precise watering. UNIQUE PATENTED EMITTER DESIGN WITH PHYSICAL ROOT BARRIER Offset flow path, extra large bath area and raised outlet prevent root intrusion without chemical reliance. PRESSURE COMPENSATING Precise and equal amounts of water are delivered over a broad pressure range. CONTINUOUS SELF-FLUSHING EMITTER DESIGN Flushes debris as it is detected, throughout operation, not just at the beginning or end of a cycle, ensuring uninterrupted emitter operation. EMITTER WITH ANTI-SIPHON FEATURE Prevents ingestion of debris into tubing caused by vacuum. SELF-CONTAINED, ONE-PIECE DRIPLINE CONSTRUCTION Assures reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 7” radius. For on-surface installations withstands heat and direct sun. MAKES INSTALLATION QUICKER Does not require automatic flush valve for on-surface or subsurface installations. Use manual flush valves at exhaust headers. QUALIFIES FOR USE ON LEED PROJECTS Exploded View of Techline CV Emitter

16 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® CV TECHLINE CALCULATOR DOWNLOAD FROM THE APP STORE OR GOOGLE PLAY FLOW PER 100 FEET 12” 18” 24” 0.26 EMITTER 0.42 EMITTER 0.92 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM GPH GPM 26.4 0.44 42.3 0.71 60.8 1.01 92.5 1.54 17.6 0.29 28.2 0.47 40.5 0.68 61.6 1.03 - - - - 30.4 0.51 46.2 0.77 0.61 EMITTER INLET PRESSURE MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi EMITTER SPACING 12” 18“ 24” EMITTER FLOW (GPH) 0.26 0.42 0.61 0.92 0.26 0.42 0.61 0.92 0.61 0.92 331 242 190 144 468 344 270 204 342 260 413 302 238 180 584 429 338 257 430 326 518 380 299 227 737 540 426 323 542 412 594 436 343 260 845 620 489 371 622 472 655 480 378 287 932 684 539 410 686 522 681 500 393 298 969 713 561 426 716 544 SPECIFYING MODEL NUMBER TLCV4-1210 3 1 A SAMPLE MODEL NUMBER Techline CV Dripline = TLCV A EMITTER SPACING 2 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 3 100’ 250’ 500‘ 1,000’ = 01 = 025 = 05 = 10 EMITTER FLOW RATE 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH = 26 = 4 = 6 = 9 1 2 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 58 PRESSURE (psi) FLOW RATE (GPH) 0.61 GPH 0.42 GPH 0.26 GPH 0.92 GPH Techline CV emitters open at 14.5 psi and close at 2 psi. FLOW RATE VS. PRESSURE FLOW CODE EMITTER SPACING COIL LENGTH MODEL NUMBER TLCVX-1201 TLCVX-12025 TLCVX-1210 TLCVX-1801 TLCVX-18025 TLCVX-1810 TLCVX-2401 TLCVX-24025 TLCVX-2410 12” 18” 24“ 100’ 250’ 1,000’ 100’ 250’ 1,000’ 100’ 250’ 1,000‘ 26 4 6 9 FLOW RATE 0.26 0.42 0.61 0.92 ORDERING INFORMATION BLANK TUBING 100’ 250’ 500‘ 1,000’ TLCV001 TLCV0025 TLCV005 TLCV010 COIL LENGTH MODEL NUMBER * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.

NETAFIM USA Landscape & Turf Product Catalog | 17 TECHLINE® DL 17mm DRIPLINE Maximum Uniformity in Subsurface and On-surface Including Slopes. FEATURES & BENEFITS THE FIRST ANTI-SIPHON EMITTER IN LANDSCAPE DRIPLINE Emitter manufactured and successfully used in harsh agricultural applications since 2000. Emitter is pressure compensating and continuous flushing. EMITTER WITH ANTI-SIPHON FEATURE Prevents ingestion of debris into tubing caused by vacuum. SELF-CONTAINED, ONE-PIECE DRIPLINE CONSTRUCTION Assures reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 7” radius. For on-surface installations withstands heat and direct sun. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Curved, angular or narrow planting areas • High traffic/high liability areas • Areas subject to vandalism • High wind areas • Turf, shrubs, trees • Slopes • At-grade windows • Sports turf SPECIFICATIONS • Emitter flow rates: 0.26, 0.42, 0.61 and 0.92 GPH • Emitter spacings: 12”, 18” or 24” (24” available in 0.61 and 0.92 GPH only) • Pressure compensation range: 6 to 58 psi • Bending radius: 7” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 6 psi • Tubing diameter: 0.66” OD; 0.56” ID; 0.050“ wall • Coil lengths: 100’, 250’, 500‘, 1,000’ • Recommended minimum filtration: 120 mesh • Diaphragm made of silicon • ISO 9261 Standard Compliance TECHLINE DL QUALIFIES FOR USE ON LEED PROJECTS TECHNOLOGY LARGEST DRIPPER INLET FILTER AREA Prevents penetration of dirt particles into the dripper. Improves dripper performance with expanded tooth pattern maximizing flow path area allowing debris to pass easily through the dripper. INDUSTRY’S WIDEST FLOW PATH Allows particles through short flow path. CHEMICAL RESISTANT MOLDED SILICON SELF-FLUSHING, SELF-ADJUSTING DIAPHRAGM Movement maintains a constant pressure differential within the water passage resulting in a uniform flow rate under a wide pressure range and varying water quality.

18 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® DL FLOW PER 100 FEET 12” 18” 24” 0.26 EMITTER 0.42 EMITTER 0.92 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM GPH GPM 26.4 0.44 42.3 0.71 60.8 1.01 92.5 1.54 17.6 0.29 28.2 0.47 40.5 0.68 61.6 1.03 - - - - 30.4 0.51 46.2 0.77 0.61 EMITTER FLOW RATE VS. PRESSURE 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 PRESSURE (psi) FLOW RATE (GPH) 0.61 GPH 0.42 GPH 0.26 GPH 0.92 GPH 58 MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) INLET PRESSURE 10 psi 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi 18” 24” 12” EMITTER SPACING EMITTER FLOW (GPH) 0.42 0.26 0.26 0.42 0.61 0.61 0.92 0.92 0.61 0.92 332 244 192 146 461 338 267 203 332 252 512 376 297 225 711 524 413 314 518 394 569 418 330 250 792 582 459 350 576 438 659 484 382 290 918 675 533 405 670 510 730 537 423 321 1,019 750 591 450 742 566 790 581 458 348 1,103 812 641 488 804 612 818 601 474 360 1,140 840 663 504 832 634 SPECIFYING MODEL NUMBER TLDL4-1210 3 1 A SAMPLE MODEL NUMBER Techline DL Dripline = TLDL A EMITTER SPACING 2 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 3 100’ 250’ 500‘ 1,000’ = 01 = 025 = 05 = 10 EMITTER FLOW RATE 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH = 26 = 4 = 6 = 9 1 2 FLOW CODE EMITTER SPACING COIL LENGTH *MODEL NUMBER TLDLX-1201 TLDLX-12025 TLDLX-1205 TLDLX-1210 TLDLX-1801 TLDLX-18025 TLDLX-1805 TLDLX-1810 TLDLX-2410 12” 18” 24“ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 1,000‘ 26 4 6 9 FLOW RATE 0.26 0.42 0.61 0.92 ORDERING INFORMATION BLANK TUBING 100’ 250‘ 500‘ 1,000’ TLDL-001 TLDL-0025 TLDL-005 TLDL-010 COIL LENGTH MODEL NUMBER * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.

NETAFIM USA Landscape & Turf Product Catalog | 19 TECHLINE® RW & RWP 17mm DRIPLINE For Reclaimed Water Use. TECHLINE RW& RWP QUALIFIES FOR USE ON LEED PROJECTS Purple striped dripline TECHLINE RW Solid purple dripline TECHLINE RWP APPLICATIONS • For subsurface or on-surface irrigation with non-potable/ reclaimed water and soil loading • Reclaimed (recycled) water use • For irrigation with non-potable/ reclaimed water and soil loading FEATURES & BENEFITS UNIQUE PATENTED EMITTER DESIGN WITH P HYSICAL ROOT BARRIER Emitters prevent root intrusion without chemical reliance. PRESSURE COMPENSATING Precise and equal amounts of water are delivered over a broad pressure range. CONTINUOUS SELF-FLUSHING EMITTER DESIGN Flushes debris as it is detected, throughout operation, not just at the beginning or end of a cycle, ensuring uninterrupted emitter operation. TECHLINE RW AND RWP ARE DESIGNED FOR RECLAIMED WATER USE ONLY Reclaimed, reuse or recycled water is municipally-treated, non-potable water deemed appropriate for use in irrigation systems and not wastewater being dispersed into the soil for additional treatment. Please consult your local Water Management District for regulations regarding the type of water being used, and its proper system design. Netafim USA can provide assistance on drip dispersal that uses primary or secondary and tertiary wastewater. Please contact Netafim USA Customer Service for more information. EMITTER WITH ANTI-SIPHON FEATURE Prevents ingestion of debris into tubing caused by vacuum. SELF-CONTAINED, ONE-PIECE DRIPLINE CONSTRUCTION Assures reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 7” radius. For on-surface installations withstands heat and direct sun. SPECIFICATIONS • Emitter flow rates: 0.26, 0.42, 0.61 and 0.92 GPH • Emitter spacings: 12”, 18” and 24” • Pressure compensation range: 7 to 58 psi • Bending radius: 7” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 6 psi • Tubing diameter: 0.66“ OD; 0.56” ID; 0.050” wall • Coil lengths: 250’ and 1,000’ • Recommended minimum filtration: 120 mesh • Diaphragm made of silicon • ISO 9261 Standard Compliance

20 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® RW & RWP MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) INLET PRESSURE 10 psi 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi 18” 24” 12” EMITTER SPACING EMITTER FLOW (GPH) 0.42 0.26 0.26 0.42 0.61 0.61 0.92 0.92 0.61 0.92 332 244 192 146 461 338 267 203 332 252 512 376 297 225 711 524 413 314 518 394 569 418 330 250 792 582 459 350 576 438 659 484 382 290 918 675 533 405 670 510 730 537 423 321 1,019 750 591 450 742 566 790 581 458 348 1,103 812 641 488 804 612 818 601 474 360 1,140 840 663 504 832 634 FLOW RATE VS. PRESSURE 1.0 0.8 0.6 0.4 0.2 0 10 0 20 30 40 50 PRESSURE (psi) FLOW RATE (GPH) 0.92 GPH 0.61 GPH 0.42 GPH 58 0.26 GPH FLOW PER 100 FEET 12” 18” 24” 0.26 EMITTER 0.42 EMITTER 0.92 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM GPH GPM 26.4 0.44 42.3 0.71 60.8 1.01 92.5 1.54 17.6 0.29 28.2 0.47 40.5 0.68 61.6 1.03 - - - - 30.4 0.51 46.2 0.77 0.61 EMITTER SPECIFYING MODEL NUMBER TLRW4-1210 3 1 A SAMPLE MODEL NUMBER Techline RW Dripline = TLRW Techline RWP Dripline = TLRWP A EMITTER SPACING 2 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 3 250’ 1,000’ = 025 = 10 EMITTER FLOW RATE 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH = 26 = 4 = 6 = 9 1 2 FLOW CODE EMITTER SPACING COIL LENGTH *RW MODEL NUMBER TLRWX-1201 TLRWX-12025 TLRWX-1205 TLRWX-1210 TLRWX-1801 TLRWX-18025 TLRWX-1805 TLRWX-1810 TLRWX-2410 *RWP MODEL NUMBER TLRWPX-1201 TLRWPX-12025 TLRWPX-1205 TLRWPX-1210 TLRWPX-1801 TLRWPX-18025 TLRWPX-1805 TLRWPX-1810 TLRWPX-2410 12” 18” 24“ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 1,000‘ 26 4 6 9 FLOW RATE 0.26 0.42 0.61 0.92 ORDERING INFORMATION BLANK TUBING 250‘ 250’ 1,000‘ 1,000’ TLRW-0025 TLRWP-0025 TLRW-010 TLRWP-010 COIL LENGTH MODEL NUMBER * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.

NETAFIM USA Landscape & Turf Product Catalog | 21 TECHLINE® EZ 12mm DRIPLINE Ideal for Small and Medium Areas. QUALIFIES FOR USE ON LEED PROJECTS FEATURES & BENEFITS THE FIRST ANTI-SIPHON EMITTER IN LANDSCAPE DRIPLINE Emitter manufactured and successfully used in harsh agricultural applications since 2000. Emitter is pressure compensating and continuous flushing. LESS VISUALLY OBTRUSIVE 12mm diameter tubing is less noticeable in landscape installations. EMITTER WITH ANTI-SIPHON FEATURE Prevents ingestion of debris into tubing caused by vacuum. SELF-CONTAINED, ONE-PIECE DRIPLINE CONSTRUCTION Assures reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 6” radius. For on-surface installations withstands heat and direct sun. MORE COST EFFECTIVE IN SMALLER BED AREAS 24% smaller diameter tubing. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Bed areas that require shorter lateral lengths • Areas subject to vandalism • Planting areas • Curved, narrow, and angular planting areas • Rooftop gardens • Vegetable gardens • Green walls • High traffic or high liability areas • Raised planters SPECIFICATIONS • Emitter flow rates: 0.26, 0.42, 0.61 and 0.92 GPH • Emitter spacings: 6”, 12” and 18” (6” available for 0.26 and 0.42 GPH only) • Uses 12mm Netafim insert fittings or any compression fitting for 0.510” O.D. diameter tubing • Pressure compensation range: 6 to 58 psi • Bending radius: 6” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 6 psi • Tubing diameter: 0.510” O.D.; 0.426“ I.D. • Coil lengths: 200’, 250’, 300’, 500’, 1,000’ • Recommended minimum filtration: 120 mesh • Diaphragm made of silicon • ISO 9261 Standard Compliance

22 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® EZ FLOW RATE VS. PRESSURE 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 PRESSURE (psi) FLOW RATE (GPH) 0.61 GPH 0.42 GPH 0.26 GPH 0.92 GPH 58 MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) INLET PRESSURE 10 psi 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi 18” 12” 6” EMITTER SPACING EMITTER FLOW (GPH) 0.42 0.26 0.26 0.42 0.61 0.61 0.92 0.26 0.42 0.92 93 68 173 126 99 75 243 179 140 105 143 105 265 194 153 116 374 275 216 164 158 116 294 216 170 129 416 305 240 182 183 134 340 250 196 149 480 353 278 212 202 148 377 276 218 165 533 392 308 234 219 160 407 299 235 178 576 423 333 254 226 166 421 309 243 184 596 438 345 263 FLOW PER 100 FEET 6” 12” 18” 0.26 EMITTER 0.42 EMITTER 0.92 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM GPH GPM 52.8 0.88 84.0 1.40 Not Standard Not Standard 26.4 0.44 42.3 0.71 60.8 1.01 92.5 1.54 17.6 0.29 28.2 0.47 40.5 0.68 61.6 1.03 0.61 EMITTER SPECIFYING MODEL NUMBER TLEZ4-1210 3 1 A SAMPLE MODEL NUMBER Techline EZ Dripline = TLEZ A EMITTER SPACING 2 6” 12” 18” 24” = 6 = 12 = 18 = 24 COIL LENGTH 3 EMITTER FLOW RATE 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH = 26 = 4 = 6 = 9 1 2 200’ 250‘ 300’ 500‘ 1,000’ = 02 = 025 = 03 = 05 = 10 FLOW CODE EMITTER SPACING COIL LENGTH *MODEL NUMBER TLEZX-601 TLEZX-6025 TLEZX-605 TLEZX-610 TLEZX-1201 TLEZX-12025 TLEZX-1205 TLEZX-1210 TLEZX-1801 TLEZX-18025 TLEZX-1805 TLEZX-1810 TLEZX-2410 6” 12” 18” 24“ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 100’ 250’ 500‘ 1,000’ 1,000‘ 26 4 6 9 FLOW RATE 0.26 0.42 0.61 0.92 ORDERING INFORMATION BLANK TUBING 200’ 250‘ 300’ 500‘ 1,000’ TLEZ-02 TLEZ-025 TLEZ-03 TLEZ-05 TLEZ-10 COIL LENGTH MODEL NUMBER * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.

NETAFIM USA Landscape & Turf Product Catalog | 23 12mm & 17mm FITTINGS For Techline® Copper, HCVXR-RW/RWP, CV XR, CV, DL, RW and RWP. APPLICATIONS • Fits Techline Copper, HCVXR-RW/RWP, CV XR, CV, DL, RW and RWP Driplines, and PE irrigation hose SPECIFICATIONS • 17mm acceptable hose sizes: 0.56” - 0.60” inside diameter • 12mm acceptable hose size: 0.426” inside diameter FEATURES & BENEFITS BARBED FITTINGS For secure fit and easy installation without clamps, glue or tools. UV RESISTANT Withstands heat, direct sun and harsh chemicals. ONE-PIECE CONSTRUCTION For added strength, durability and long-term performance. ALLOWS FOR EASY ON-SITE INSPECTION For proper fitting and installation. INSERT ADAPTER FOR 1” OR LARGER PE (requires 11mm or 7/16” punch) 17mm Model TLIAPE-B INSERT ADAPTER FOR 1 1/2” OR LARGER PVC (requires TDBIT16.5) 17mm Model TLIAPVC-B 12mm Model T12IAPVC-B 1/2” MPT ADAPTER 17mm Model TL050MA 12mm Model TL12050MA INSERT COUPLING 17mm Model TLCOUP 12mm Model TL12COUP INSERT CROSS (requires 11mm or 7/16” punch) 17mm Model TLCROS 12mm Model T12CROS EMITTER MICRO-TUBING ADAPTER 17mm Model TLMTUBEADP 3/4” MPT ADAPTER 17mm Model TL075MA 12mm Model T12075MA INSERT ELBOW 17mm Model TLELL 12mm Model T12LELL INSERT TEE 17mm Model TLTEE 12mm Model T12TEE 3/4” MPT x ‘V’ 17mm Model TL2W075MA 12mm Model T122W075MA COMBINATION TEE INS x INS x 1/2” FPT 17mm Model TL050FTEE INS x INS x 3/4” FPT 17mm Model TL075FTEE 12mm Model T12075FTEE MPT = Male Pipe Thread INS x INS = Insert x Insert FPT = Female Pipe Thread MANUAL FLUSH VALVE 12mmModel T12SOV REDUCING COUPLING 12MM BARB x 17MM BARB Model T12RCOUP MANUAL FLUSH VALVE Model TLSOV FIGURE 8 LINE END Model TLFIG8

24 | Landscape & Turf Product Catalog NETAFIM USA APPLICATIONS • Fits HCVXR, HCVXR-RW and RWP, CVXR, CV, DL, RW and RWP driplines, and PE tubing SPECIFICATIONS • Tubing internal diameter: 0.530” - 0.560“ • Tubing wall thickness: 0.035” - 0.050“ • Tubing outside diameter: 0.600” - 0.660“ • Working temperature range: 32˚ F - 140˚ F • Operating pressure: 0 to 100 psi • Pull-out resistance: 67 ft-lbs. • Warranty: 10 years for below ground (subsurface) installations 5 years for above ground (surface) installations FEATURES & BENEFITS SIMPLE AND EFFICIENT INSTALLATION WITH REDUCED PHYSICAL STRAIN Ergonomic design enables quick field installation and reuse while reducing physical strain on installation crews. INDUSTRY LEADING PRESSURE RATING Get maximum performance and durability with our industry leading pressure rating and pullout resistance. WARRANTY ENSURES CONFIDENCE Specifiers, contractors and distributors will have peace of mind with our warranty - 10 years for subsurface installations and 5 years for surface installations. SIZE RANGE FLEXIBILITY 16mm and 17mm outside diameter size range simplifies the job for designers and contractors. TECHLOCK 3/4” MPT ADAPTER Model TLCK075MA TECHLOCK COUPLER Model TLCKCOUP TECHLOCK ELBOW Model TLCKELL TECHLOCK TEE Model TLCKTEE TECHLOCK ELBOW FITTING Barb ends fit securely on the tubing while the techlock threaded caps and compression rings ensure a tight seal. Compression Ring Techlock Threaded Cap TECHLOCK FITTINGS For 16mm and 17mm Techline® and Polyethylene (PE) Tubing. INSTALLATION TOOLS WHEELBARROW TUBING DISPENSER Model WBTD PRESSURE GAUGE (0-30 psi) Model GAUGE30 PRESSURE GAUGE (0-100 psi) Model GAUGE100 SHRADER VALVE (1/8” MPT) Model 61APS1/8 PRESSURE GAUGE NEEDLE Model 6809091 DRILL BIT FOR PVC INSERT ADAPTER Model TDBIT16.5

NETAFIM USA Landscape & Turf Product Catalog | 25 DRIPLINE COMPONENTS AIR/VACUUM RELIEF AIR VENTS APPLICATIONS 1/2” Air Vents • Install in subsurface systems 3/4“, 1” and 2” Guardian Air Vents • Install in subsurface systems • On sloping terrain to prevent collapsing of pipes caused by vacuum when pipe networks drain • For air discharge during system start-up DRIPLINE COMPONENTS COMBINATION AIR VENTS APPLICATIONS • For discharge of large volumes of air, along mains and at the end of mainlines • Place before water meters and automatic metering valves for accurate flow readings • Place at high points in pipe network or upstream of manifolds MPT = Male Pipe Thread FPT = Female Pipe Thread SPECIFICATIONS 1/2” Air Vents • Maximum operating pressure: 140 psi 3/4“, 1” And 2” Guardian Air Vents • Maximum operating pressure: 150 psi • Made of corrosion-resistant reinforced UV protected composite materials - no metal parts to rust or corrode, no need for spare parts MPT = Male Pipe Thread COMBINATION 1” MPT Model 65ARIB1-150 MINI 1/2” MPT Model AV-COMBO-050 3/4” MPT Model AV-COMBO-075 SPECIFICATIONS Mini • Continuous acting • Maximum operating pressure: 150 psi • Sizes: ½” and ¾” MPT (2.4”w x 4.5”h) Combination • Continuous acting • Maximum operating pressure: 150 psi • Size: 1” MPT (3.9”w x 5.5”h) Guardian Air/Vacuum Relief Vent Mini Combination Air Vent GUARDIAN 1” MPT Model 65ARIA100 3/4” MPT Model 65ARIA075 1/2” MPT Model TLAVRV 2” GUARDIAN FPT Model 65ARIA2

26 | Landscape & Turf Product Catalog NETAFIM USA DRIPLINE COMPONENTS AUTOMATIC FLUSH VALVES APPLICATIONS • Drip irrigation systems • Clean or dirty water SPECIFICATIONS • Not required with Techline Copper and CV • Flushing water volume: approximately 1 gallon per cycle • Maximum zone flow rate per valve flush: 15 GPM • Minimum pressure required: 1.5 psi • Maximum operating pressure: 57 psi FEATURES & BENEFITS FLUSHING REDUCES SEDIMENT BUILD-UP Eliminates clogging. Promotes long-term performance of the drip irrigation system. AUTOMATIC CLEANING OPERATION Eliminates periodic manual flushing. UNIQUE DESIGN REACTS TO FLOW, NOT PRESSURE Allows operation even at full line pressure. DISASSEMBLES FOR WINTERIZATION ‘BLOWOUT’ Protects your drip system. DRIPLINE COMPONENTS INLINE CHECK VALVE APPLICATIONS • Prevents backflow of water and drainage of the system into low areas • Eliminates the need for system water refill at the beginning of the next irrigation cycle • For irrigating slopes where draining of the headers and laterals is common (13.4 feet of holdback) SPECIFICATIONS • Flow rate: 0.9 - 4.4 GPM • Closing pressure: 5.8 psi (13.4 feet column of water) • Opening pressure: 10.2 psi FEATURES & BENEFITS MANUFACTURED FROM DURABLE MATERIALS For reliable operation. LARGE INLET OPENING Reduces headloss. WIDE FLOW RANGE For use in a number of applications. IN-LINE CHECK VALVE 1/2” MPT Model TLCV050M1-B FLOW RATE (GPM) VS. PRESSURE LOSS (psi) 0.5 FLOW RATE VS. PRESSURE LOSS 1 1.5 2 2.5 3 3.5 4 4.5 - 0.22 0.54 0.96 1.55 2.25 2.99 4.04 - MPT = Male Pipe Thread MPT = Male Pipe Thread AUTOMATIC FLUSH VALVE INSERT INLET Model TLFV-1 AUTOMATIC FLUSH VALVE 1/2” MPT INLET Model TL050MFV-1 As irrigation starts, valve flushes out dirt particles in the open position. After flushing, the valve closes and normal system operation begins. Diaphragm in open position allows flushing.